Scheimpflug photography in clinical ophthalmology. A review
- https://pubmed.ncbi.nlm.nih.gov/1484683/
- Scheimpflug photography in clinical ophthalmology. A review The development of a slitlamp camera system based on the Scheimpflug principle with image analysis has been a major improvement in lens and cataract research.
Scheimpflug Analysis - American Academy of Ophthalmology
- https://www.aao.org/focalpointssnippetdetail.aspx?id=5b89b5e8-19d4-4e49-9edf-d791ce4497a1
- In the Pentacam (Oculus, Lynwood, WA), a rotating Scheimpflug camera takes a maximum of 2 seconds to generate a complete image of the anterior segment. Any eye movement is detected by a second camera and corrected for in the process. A 3-dimensional model of the anterior segment may be calculated from as many as 25,000 true elevation points.
[Scheimpflug photography of the lens] - PubMed
- https://pubmed.ncbi.nlm.nih.gov/2676791/
- The introduction of Scheimpflug photography of the anterior eye segment, the construction of appropriate equipment, and the development of procedures for image analysis have decisively influenced clinical and experimental research on the anterior eye segment.
Scheimpflug photography study of ophthalmic viscosurgical
- https://pubmed.ncbi.nlm.nih.gov/12663026/
- Scheimpflug photographs were taken using a Nidek EAS-1000 instrument before surgery (control), after injection of the OVD, after continuous curvilinear capsulorhexis (CCC), and after lens extraction by phacoemulsification. Differences in the ACD with a P value less than 0.05 were considered statistically significant.
Scheimpflug photography in clinical ophthalmology. A review.
- https://europepmc.org/article/MED/1484683
- The purpose of this paper is to summarize and review the application of Scheimpflug photography in clinical ophthalmology and to show possibilities and indications for the use of the Scheimpflug technique in clinical studies. Full text links Read article at publisher's site (DOI): 10.1159/000267208 Citations & impact Impact metrics 9 Citations
The use of Scheimpflug photography in the documentation of
- https://pubmed.ncbi.nlm.nih.gov/8577457/
- Further to the clinical applications of the Scheimpflug photography worked out by us and summed up once again in this paper, it also presents a widening of the scope hence available within ophthalmological teaching methods, which we can hardly do without these days.
Scheimpflug imaging - American Academy of Ophthalmology
- https://www.aao.org/image/scheimpflug-imaging-10
- Example of Scheimpflug imaging. a. Preoperative lens densitometry. The region of interest is marked to measure average lens density. b. Postoperative decrease in densitometry after dysfunctional lens
Photography of the anterior eye segment according to …
- https://pubmed.ncbi.nlm.nih.gov/19338611/
- Photography of the anterior eye segment according to Scheimpflug's principle: options and limitations - a review Abstract Scheimpflug photography and densitometric image analysis are very precise techniques for light scattering measurement and biometry in …
Scheimpflug imaging - American Academy of Ophthalmology
- https://www.aao.org/image/scheimpflug-imaging-8
- Scheimpflug imaging
Evaluation of Pachymetric Measurements with Scheimpflug …
- https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4129168/
- Scheimpflug-based, ultrasound (US) based, slit scanning, and optical coherence tomography (OCT) based systems allow the clinician to obtain corneal pachymetric information. Ultrasonic biometry which was the most commonly used method for CT measurements until recently has some limitations.